Checking the quota counts
1 If your interview script is running, complete or stop the interview.
2 In UNICOM Intelligence Professional, open the mrScriptBasic script called DebugQuotas.mrs, which by default is installed in this folder:
[INSTALL_FOLDER]\IBM\SPSS\DataCollection\<version>\DDL\Scripts\General\mrScriptBasic
3 Edit the mrScriptBasic script to change the values of the following parameters:
PROJECT_NAME
The name of your interview script file, without the .mdd extension.
DEBUGQUOTA_DATASOURCE
The value you assigned to “Debug Quotas: Data Source Name” in UNICOM Intelligence Professional Options. See “To Test a Quota” above for more information about this option.
DEBUGQUOTA_DATABASE
The value you assigned to “Debug Quotas: Database Name” in UNICOM Intelligence Professional Options. See “To Test a Quota” above for more information about this option.
4 Run the mrScriptBasic script.
5 Open the appropriate survey (.mdd), if it is not already open, and from the Tools menu, choose Tools > Quota > Enable Debugging.
6 Ensure that the Tools > Options > Testing > Report script option identifies the appropriate script file. If required, click Browse to select another file.
7 From the Tools menu, choose Tools > Quota > View Report.
After a brief pause, an Excel worksheet opens. For each quota category, the worksheet shows the count of completed and pending interviews and the target value.
See also