Log settings
Registry settings for log files for UNICOM Intelligence interviews are stored under the following key:
HKEY_LOCAL_MACHINE\Software\SPSS\mrInterview\3\Log
Settings
Directory
The folder to which UNICOM Intelligence Interviewer log files will be written.
Default value: The installation default is:
[INSTALL_FOLDER]\IBM\SPSS\DataCollection\<version>\Interviewer Server Administration\Logs
Filter
The log levels to omit from the log. The log level filter is a bit field, with each bit representing a log level to omit. For example, to disable trace and script logging, set the filter to 0x50; that is, 0x10 (trace) + 0x40 (script). See
Logging levels for more information.
Default value: 0 (the installation default is 0x10 which filters out trace bugs)
MaxFiles
The number of log files to create in the log file chain before the oldest file is deleted.
Default value: 50
MaxFileSizeInKB
The size in Kbytes at which a new log file is created.
Default value: 100 (the installation default is 1000)
More information
See
Log files for more logging information.