ReadSoft FORMS numeric field options
UNICOM Intelligence Interviewer - Paper/Scan Add‑on Options: Numeric Fields tab
The settings on the Numeric Fields tab in the UNICOM Intelligence Interviewer - Paper/Scan Add‑on Options dialog determine the properties of the numeric character fields that are created in ReadSoft FORMS Manager when you run the Transfer to Scanning Software command in UNICOM Intelligence Interviewer - Paper/Scan Add‑on. UNICOM Intelligence Interviewer - Paper/Scan Add‑on creates numeric format character fields for numeric responses.
Specify the options that you want for all or most numeric responses. If any numeric responses require different or additional property settings, go into ReadSoft FORMS and make the changes manually after you have run the Transfer to Scanning Software command.
Must be filled-in
Causes ReadSoft FORMS Verify to display character fields that have not been filled in.
Confirm
Causes ReadSoft FORMS Verify to prompt for confirmation of the interpreted value of every numeric response.
Mass verify
Causes ReadSoft FORMS to give character fields the mass verify status. Fields with this status must be confirmed before they can receive a higher status.
Confirm handwritten
Causes ReadSoft FORMS Verify to prompt for manual confirmation when the field contains handwritten characters.
Retype always
Causes ReadSoft FORMS Verify to prompt you to retype the field.
Retype handwritten
Causes ReadSoft FORMS Verify to prompt you to retype fields that contain handwritten characters.
Ignore strikeout
Causes ReadSoft FORMS to treat character fields that have been crossed out as blank fields.
Security
Defines the threshold at which ReadSoft FORMS accepts or rejects uncertain characters.
Field complement
Controls the circumstances under which ReadSoft FORMS prompts you to enter additional information in an associated field. UNICOM Intelligence Interviewer - Paper/Scan Add‑on Transfer ignores data in numeric field complements. So if you are using UNICOM Intelligence Interviewer - Paper/Scan Add‑on Transfer to transfer the scanned data, deselect these options.
▪If empty. Causes ReadSoft FORMS to prompt you for the complement when the character field is empty.
▪If filled-in. Causes ReadSoft FORMS to prompt you for the complement when the character field has been filled in.